Measurement technology for highest reliability in every application
VEGA develops and manufactures sensors for the measurement of level, point level and pressure as well as equipment and software for integration into process control systems. VEGA's measurement technology sets new standards in reliability, accuracy and economy for all media and process conditions.
Choose between the different measuring principles for level measurement of liquids.
» VEGAPULS WL 61
Measuring range up to 15 m
Process fitting thread G1½ mounting strap compression flanges from DN 80, 3"
Process temperature -40 … +80 °C
Process pressure -1 … +2 bar (-100 … +200 kPa)
Measuring precision ±2 mm
| |
» VEGAPULS 61
Measuring range up to 35 m
Process fitting thread G1½, 1½ NPT mounting strap compression flanges from DN 80, 3"
Process temperature -40 … +80 °C
Process pressure -1 … +3 bar (-100 … +300 kPa)
Measuring precision +/- 2 mm
SIL qualification optionally up to SIL2
| |
» VEGAPULS 62
Measuring range up to 35 m
Process fitting thread from G1½, 1½ NPT flanges from DN 50, 2"
Process temperature -200 … +450 °C
Process pressure -1 … +160 bar (-100…+16000 kPa)
Measuring precision +/- 2 mm
SIL qualification optionally up to SIL2
| |
» VEGAPULS 63
Measuring range up to 35 m
Process fitting hygienic fittings boltings flanges from DN 50, 2"
Process temperature -200 … +200 °C
Process pressure -1 … +16 bar (-100 … +1600 kPa)
Measuring precision +/- 2 mm
SIL qualification optionally up to SIL2
| |
» VEGAPULS 65
Measuring range up to 35 m
Process fitting thread from G1½, 1½ NPT flanges from DN 50, 2"
Process temperature -40 … +150 °C
Process pressure -1 … +16 bar (-100 … +1600 kPa)
Measurement accuracy +/- 8 mm
SIL qualification optionally up to SIL2
| |
» VEGAPULS 66
Measuring range up to 35 m
Process fitting flanges up to DN 50, 2"
Process temperature -60 … +400 °C
Process pressure -1 … +160 bar (-100 … +16000 kPa)
Measurement accuracy +/- 8 mm
SIL qualification optionally up to SIL2
| |
|
» VEGAFLEX 81
Version exchangeable cable probe (ø 2 mm, ø 4 mm) exchangeable rod probe (ø 8 mm) coax probe (ø 21.3, mm, ø 42 mm)
Measuring range
cable probe up to 75 m rod probe up to 6 m coax probe up to 6 m
Process fitting thread from G¾, ¾ NPT flanges from DN 25, 1"
Process temperature -40 … +200 °C
Process pressure -1 … +40 bar (-100 … +4000 kPa)
| |
» VEGAFLEX 83
Version cable probe (ø 4 mm) rod probe (ø 8 mm)
Measuring range cable probe up to 32 m rod probe up to 4 m
Process fitting flanges from DN 25, 1" hygienic fittings
Process temperature -40 … +150 °C
Process pressure -1 … +16 bar (-100 … +1600 kPa)
| |
» VEGAFLEX 86
Version exchangebale cable probe (ø 2 mm, ø 4 mm) exchangeable rod probe (ø 16 mm) coax probe (ø 42 mm)
Measuring range cable probe up to 75 m rod probe up to 6 m coax probe up to 6 m
Process fitting thread from G1½ , 1½ NPT flanges from DN 50, 2"
Process temperature -196 … +450 °C
Process pressure -1 … +400 bar (-100 … +40000 kPa)
| |
» VEGAFLEX 61
Version exchangeable cable (ø 2 mm, ø 4 mm) exchangeable rod (ø 6 mm)
Measuring range cable: up to 32 m rod: up to 4 m
Process fitting thread from G¾, ¾ NPT flanges from DN 25, 1"
Process temperature -40 … +150 °C
Process pressure -1 … +40 bar (-100 … +4000 kPa)
SIL qualification optionally up to SIL2
| |
» VEGAFLEX 62
Version exchangeable cable (ø 6 mm) exchangeable rod (ø 16 mm)
Measuring range cable: up to 60 m rod: up to 6 m
Process fitting thread from G1½, 1½ NPT flanges from DN 50, 2"
Process temperature -40 … +150 °C
Process pressure -1 … +40 bar (-100 … +4000 kPa)
SIL qualification optionally up to SIL2
| |
» VEGAFLEX 63
Version cable (ø 4 mm) rod (ø 10 mm)
Measuring range cable up to 32 m rod up to 4 m
Process fitting flanges from DN 50, 2“ Clamp from 1"
Process temperature -40 … +150 °C
Process pressure -0.5 … +16 bar (-50… +1600 kPa)
SIL qualification optionally up to SIL2
| |
» VEGAFLEX 65
Process fitting thread from G¾, ¾ NPT flanges from DN 25, 1"
Process temperature -40 … +150 °C
Process pressure -1 … +40 bar (-100 … +4000 kPa)
SIL qualification optionally up to SIL2
| |
» VEGAFLEX 66
Version exchangeable cable (from ø 4 mm) exchangeable rod (from ø 6 mm) coax probe
Measuring range cable up to 60 m rod up to 6 m coax up to 6 m
Process fitting thread from G¾, ¾ NPT flanges from DN 40, 2"
Process temperature -200 … +400 °C
Process pressure -1 … +400 bar (-100 … +40000 kPa)
SIL qualification optionally up to SIL2
| |
» VEGAFLEX 67
Version exchangeable cable (ø 4 mm) exchangeable rod (ø 6 mm) coax probe
Measuring range cable up to 60 m rod up to 6 m coax up to 6 m
Process fitting thread from G¾, ¾ NPT flanges from DN 25, 1"
Process temperature -200 … +400 °C
Process pressure -1 … +400 bar (-100 … +40000 kPa)
| |
|
» VEGASON 61
Measuring range in liquids: 0.25 … 5 m in bulk solids: 0.25 … 2 m
Process fitting thread G1½, 1½ NPT
Process temperature -40 … +80 °C
Process pressure -0,2 … +2 bar (-20 … +200 kPa)
SIL qualification optionally up to SIL2
| |
» VEGASON 62
Measuring range in liquids: 0.4 … 8 m in bulk solids: 0.4 … 3.5 m
Process fitting thread G2, 2 NPT
Process temperature -40 … +80 °C
Process pressure -0,2 … +2 bar (-20 … +200 kPa)
SIL qualification optionally up to SIL2
| |
» VEGASON 63
Measuring range in liquids: 0.6 … 15 m in bulk solids: 0.6 … 7 m
Process fitting compression flange DN 100 mounting strap
Process temperature -40 … +80 °C
Process pressure -0,2 … +1 bar (-20 … +100 kPa)
SIL qualification optionally up to SIL2
| |
|
» VEGACAL 62
Version partly insulated rod
Process fitting thread from G¾, ¾ NPT flanges from DN 25, 1"
Materials steel, 316L, PTFE
Process temperature -50 … +200 °C
Process pressure -1 … +64 bar (-100 … +6400 kPa)
SIL qualification optionally up to SIL2
| |
» VEGACAL 63
Version fully insulated rod
Process fitting thread from G¾, ¾ NPT flanges from DN 25, 1"
Process temperature -50 … +200 °C
Process pressure -1 … +64 bar (-100 … +6400 kPa)
SIL qualification optionally up to SIL2
| |
» VEGACAL 64
Version fully insulated rod
Process fitting thread from G¾, ¾ NPT flanges from DN 25, 1"
Process temperature -50 … +150 °C
Process pressure -1 … +64 bar (-100 … +6400 kPa)
SIL qualification optionally up to SIL2
| |
» VEGACAL 65
Version partly insulated cable
Measuring range up to 32 m
Process fitting thread from G1, 1 NPT flanges from DN 50, 1"
Process temperature -50 … +200 °C
Process pressure -1 … +64 bar (-100 … +6400 kPa)
SIL qualification optionally up to SIL2
| |
» VEGACAL 66
Version fully insulated cable
Measuring range up to 32 m
Process fitting thread from G1, 1 NPT flanges from DN 50, 2"
Process temperature -50 … +150 °C
Process pressure -1 … +40 bar (-100 … +4000 kPa)
SIL qualification optionally up to SIL2
| |
» VEGACAL 69
Process fitting flanges from DN 50, 2"
Process temperature -50 … +100 °C
Process pressure -1 … +2 bar (-100 … +200 kPa)
SIL qualification optionally up to SIL2
| |
|
» VEGABAR 66
Measuring range 0 … +25 bar (0 … +2500 kPa)
Process fitting thread from G1½, 1½ NPT flanges from DN 40, 2"
Process temperature -40 … +100 °C
Deviation of characteritics 0.1 %
SIL qualification optionally up to SIL2
| |
» VEGABAR 67
Measuring range 0 … +25 bar (0 … +2500 kPa)
Process fitting thread from G1½, 1½ NPT flanges from DN 50, 2"
Process temperature -12 … +100 °C
Deviation in characteritics 0.1 %
SIL qualification optionally up to SIL2
| |
» VEGAWELL 52
Sensor diameter from 22 mm
Measuring range 0 … +60 bar (0 … +6000 kPa)
Process temperature -20 … +80 °C
Deviation in characteritics 0.2 %; 0.1 %
| |
|
» FIBERTRAC 31
Version sensor with flexible plastic detector ø 42 mm
Mounting from outside on the vessel
SIL qualification optionally up to SIL2
| |
» SOLITRAC 31
Version sensor with PVT rod detector
Mounting from outside on the vessel
SIL qualification optionally up to SIL2
| |
|