VEGAPULS C 22
Wired radar sensor for continuous level measurement
For standard measuring tasks, IP66/IP68, Type 6P
|
|
Application area
Your benefit
- Exact measurement results independent of medium, process and environmental conditions
- Low overall height and reliable measurement even in case of flooding
- Maintenance-free operation due to non-contact 80 GHz radar technology
Suitable accessories
Mounting bracket with adjustable sensor holder |
|
Mounting bracket for ceiling mounting |
|
Mounting angle with adjustable bracket |
|
Further accessories |
Configure product
Product comparison
All documents and software for this product can be found in our Download Center.
Show all downloadsOther applications
- 15 m [Meter - Foot]
- -40 ... 80 °C [°C - °F]
- -1 ... 3 bar [Bar - kPa - psi]
- ± 2 mm
- 80 GHz
- 8°
- PVDF
- G1½, 1½ NPT, R1½
- FKM
- Housing material
- IP66/IP68 (3 bar), Type 6P
- 4 … 20 mA/HART
- Modbus
- SDI-12
- -40 ... 80 °C
- ATEX / Europe
- IEC / worldwide
- NEPSI / China
- UKR Sepro / Ukraine
- INMETRO / Brazil
- CCOE / India
- KTL Korea
- CSA / USA and Canada
- FM / USA and Candada
- TIIS / Japan
- IA
- UKEX
- Intrinsic safety "i"
- Dust explosion protection through housing "t"
- Encapsulation "m"
- FDA
- ABS
- CCS
- GL
- LR
- NK
- RINA
- WHG
- VLAREM II
- PC, PACTware and DTM
- Smartphone / Tablet / PC via Bluetooth
Drawing generator
Generate 2D and 3D drawings for your specific configuration.
Configure NowProduct catalog
Radar
Product information
VEGAPULS C 11, C 21, C 22, C 23, 11, 21, 31
Specification sheet
VEGAPULS C 22
4 … 20 mA/HART - two-wire
Operating instructions
VEGAPULS C 22
4 … 20 mA/HART - two-wire
Drawing generator
Further downloads for this product
All documents and software for this product can be found in our Download Center.
Show all downloadsVEGAMET 141
1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 142
2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 341
1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 342
2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 841
1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 842
2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 861
1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 862
2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 391
Measured value indication, simple control functions, remote enquiry of measured data. optimized for water/sewage water industry
Show ProductVEGATOR 141
Transmission of 4 ... 20 mA signals for level signalling
Show ProductVEGATOR 142
Transmission of 4 ... 20 mA signals for level signalling
Show ProductVEGADIS 82
External measured value display and adjustment for 4 ... 20 mA/HART sensors
Show ProductVEGADIS 176
Remote display for use in 4 ... 20 mA current loop
Show ProductVEGAMET 841
1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 842
2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 861
1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 862
2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductPLICSMOBILE T81
Measured data enquiry and remote parameter adjustment for a HART sensor
Show ProductVEGATRENN 141
Single channel separator for 4 … 20 m/HART sensors
Show ProductVEGATRENN 142
Double channel separator for 4 … 20 m/HART sensors
Show ProductVEGATRENN 151
Single channel separator in two-wire technology for 4 … 20 mA sensors
Show ProductVEGATRENN 152
Double channel separator in two-wire technology for 4 … 20 mA sensors
Show ProductMounting bracket with adjustable sensor holder
Mounting bracket for ceiling mounting
Mounting bracket for plastic vessel
Mounting angle with adjustable bracket
Mounting bracket 200 mm with fixed sensor holder
Hygienic adapter (G1½“) suitable for VEGAPULS 11, 21, 31, VEGAPULS C 11, C 21, C 22 and VEGAPULS Air 41
Threaded adapter 2" to 1½" suitable for VEGAPULS 11, 21, 31, VEGAPULS C 11, C 21, C 22 and VEGAPULS Air 41
Counter nut
Universal flange for VEGAPULS BASIC line
Alignment device for vessel wall mounting for radar sensors with 1½" thread
An error has occurred
An error occurred when starting the configurator. We have documented the error and are working on it.
Please try again later. Alternatively you can contact us directly.
Thank you very much for your understanding.
VEGAPULS C 22
myVEGA
With myVEGA as your personal information platform, you’ll have at your disposal numerous online functions revolving around the VEGA products.
- Configurator for the entire VEGA product range
- Information about prices and delivery times
- Order directly online
- Saving of configurations
- 2D/3D drawings of your configured instrument
- Overview of order transactions
Still no access?
Register for freeForgot password
Enter your e-mail address and we will send you a link to reset your password.
Reset password Cancel
Close