VEGABAR 83
Pressure transmitter with metallic measuring cell
With metallic measuring cell, for high pressures
|
|
Application area
Your benefit
- Maximum dependability and safety through proven technology
- High reliability through vacuum resistant version
- Universal use due to welded measuring cell
Configure product
Product comparison
All documents and software for this product can be found in our Download Center.
Show all downloadsThis pressure transmitter is the first choice for process pressure or level measurement in processes with high pressure, e.g. for
- circuit pressure measurement in hydraulic pumps
- pipeline pressure measurement
- bitumen level measurerment in asphalt mixing plants
- storage tank level measurement, e.g. for milk in dairies
- - [Meter - Foot]
- -1 ... 1000 bar [Bar - kPa - psi]
- -40 ... 200 °C [°C - °F]
- -1 ... 1000 bar [Bar - kPa - psi]
- 0.075 %
- 316L
- Alloy C22 (2.4602)
- 316Ti (1.4571)
- Alloy C4 (2.4610)
- ≥ G½, ≥ ½ NPT
- ≥ DN25, ≥ 1"
- Slotted nut ≥ DN25 - DIN 11851
- Varivent ≥ DN25
- hygienic fitting with tension flange DN32
- Hygienice flange connection ≥ DN50 DIN11864-2
- SMS 1145 DN51
- SMS DN38
- Hygienic fittings ≥ DN33 - DIN11864-1-A
- Hyg. collar clamp adapter DN40PN40 DIN11864-3-A
- Hyg. clamp connection DIN11864-3-A; DN50 Rohr ø53
- Swagelok VCR screwing
- Varivent G125
- no media contact
- Plastic
- Aluminium
- Stainless steel (precision casting)
- Stainless steel (electropolished)
- IP66/IP67
- IP66/IP68 (1 bar)
- IP68 (0,2 bar)
- IP66/IP68 (25 bar)
- IP69K
- Profibus PA
- Foundation Fieldbus
- 4 … 20 mA
- Two-wire: 4 … 20 mA/HART
- Modbus
- Secondary electronics for electronic differential pressure
- -40 ... 80 °C
- ATEX / Europe
- FM / USA
- EAC (GOST) / Belarus
- EAC (GOST) / Russia
- IEC / worldwide
- NEPSI / China
- INMETRO / Brazil
- CCOE / India
- CSA / USA and Canada
- IA
- UKEX
- Intrinsic safety "i"
- Flameproof enclosure "d"
- Dust explosion protection through housing "t"
- 3A
- EHEDG
- FDA
- EG1935/2004
- ABS
- BV
- CCS
- DNV
- LR
- RINA
- WHG
- VLAREM II
- SIL2
- PLICSCOM
- PC, PACTware and DTM
- HART-Communicator
- Software (e. g. AMS™, PDM)
- Display/adjustment module PLICSCOM
- VEGADIS 81
- VEGADIS 82
Drawing generator
Generate 2D and 3D drawings for your specific configuration.
Configure NowProduct catalog
Process pressure
Product information
VEGABAR 81, 82, 83
Specification sheet
VEGABAR 83
4 … 20 mA - two-wire
Operating instructions
VEGABAR 83
4 … 20 mA - two-wire
Drawing generator
Further downloads for this product
All documents and software for this product can be found in our Download Center.
Show all downloadsBluetooth USB adapter
Wireless adjustment of sensors and instruments via Bluetooth
Show ProductVEGADIS 81
Remote measurement value indication and adjustment of plics® sensors
Show ProductVEGADIS 82
External measured value display and adjustment for 4 ... 20 mA/HART sensors
Show ProductVEGADIS 176
Remote display for use in 4 ... 20 mA current loop
Show ProductMagnetic pen for display/adjustment module PLICSCOM
Magnetic pen for on-site adjustment
Show ProductVEGAMET 141
1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 142
2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 341
1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 342
2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 841
1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 842
2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 861
1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 862
2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 624
Measured value indication, simple control functions such as remote enquiry of measured values for a 4 ... 20 mA/HART sensor
Show ProductVEGAMET 625
Measured value indication, simple control functions such as remote enquiry of measured values for two HART sensors
Show ProductVEGAMET 391
Measured value indication, simple control functions, remote enquiry of measured data. optimized for water/sewage water industry
Show ProductVEGATOR 141
Transmission of 4 ... 20 mA signals for level signalling
Show ProductVEGATOR 142
Transmission of 4 ... 20 mA signals for level signalling
Show ProductVEGASCAN 693
Measured value indication and remote enquiry of measured data for up to 15 HART sensors
Show ProductPLICSMOBILE T81
Measured data enquiry and remote parameter adjustment for a HART sensor
Show ProductVEGATRENN 141
Single channel separator for 4 … 20 m/HART sensors
Show ProductVEGATRENN 142
Double channel separator for 4 … 20 m/HART sensors
Show ProductVEGATRENN 151
Single channel separator in two-wire technology for 4 … 20 mA sensors
Show ProductVEGATRENN 152
Double channel separator in two-wire technology for 4 … 20 mA sensors
Show ProductOvervoltage protection B 81-35
Pluggable overvoltage protection for supply and signal cables
Show ProductOvervoltage protection B 63-32
Overvoltage protection for Profibus PA and Foundation Fieldbus circuits
Show ProductOvervoltage protection B 63-48
Overvoltage protection for two-wire circuits
Show ProductOvervoltage protection B 62-30 W
Overvoltage protection for Profibus PA and Foundation Fieldbus circuits
Show ProductOvervoltage protection B 62-36 G
Overvoltage protection for two-wire circuits
Show ProductVEGACONNECT
Interface adapter between PC and VEGA instruments
Show ProductVEGABOX 03
Breather housing with ventilation filter
Show ProductEthernet switch
up to 8 RS45 pluggable
Show ProductProfibus PA/DP segment coupler
Simple segment coupler for up to 93.75 kbit/s DP-side
Show ProductBall valve fitting PASVE
The ball valve fitting PASVE™ is used for mounting of VEGABAR 54, 82 pressure transmitters with process fitting "Thread 1" suitable for PASVE.
Show ProductSiphon
Siphons according to DIN 16282 are cooling zones for protection of the pressure transmitters against too hot process media.
Show ProductWelded socket with accessory VEGABAR series 80
Welded sockets are used to connect the sensors to the process.
Show ProductBlock valve
Valves are used as shut-off device when connecting pressure transmitters to the process.
Show ProductAntenna extension PLICSMOBILE
VEGADIS adapter
For connection of an external display and adjustment unit or a Secondary sensor.
Show ProductElectronics VEGABAR series 80
Process component VEGABAR 83
PLICSMOBILE plug connector with SMA connection
Electronics PLICSMOBILE series 80
An error has occurred
An error occurred when starting the configurator. We have documented the error and are working on it.
Please try again later. Alternatively you can contact us directly.
Thank you very much for your understanding.
VEGABAR 83
myVEGA
With myVEGA as your personal information platform, you’ll have at your disposal numerous online functions revolving around the VEGA products.
- Configurator for the entire VEGA product range
- Information about prices and delivery times
- Order directly online
- Saving of configurations
- 2D/3D drawings of your configured instrument
- Overview of order transactions
Still no access?
Register for freeForgot password
Enter your e-mail address and we will send you a link to reset your password.
Reset password Cancel
Close