email public shopping_cart 0
Select shopping cart

There are already products in the shopping cart of your user account. Which shopping cart would you like to keep?

VEGAPOINT 21

Compact capacitive limit switch

For the detection of water-based liquids


VEGAPOINT 21

Application area

From DK > 1.5, from thread ½", universal connection G1" for hygiene adapter, M12, valve plug, transistor output, IO-Link, wireless operation, Ex and hygiene approvals
VEGAPOINT 21 is a low-cost limit switch for the detection of water-based liquids. The optional universal connection for hygiene adapters ensures reduced installation effort and leaner stock keeping and perfectly meets the requirements for hygienic processes in the food, beverage and pharmaceutical industries. It can be used without adjustment in the application. With IO-Link, it offers continuous digital data transmission.

Your benefit

  • Coloured 360° status display, adjustable
  • Easy integration into control systems through IO-Link communication
  • Low-cost limit switch with smallest installation dimensions

Suitable accessories

Hygienic adapter for G½"

Hygienic adapter for G1" sealing with O-ring

Hygienic adapter for G1" metallically sealing

Further accessories

Base price

$ 222.00

Detailed information on prices and delivery times can be found in the Configurator.

Staggered Prices

Quantity Price
from 1 $ 222.00
from 5 10 % Discount
from 10 Please contact us!
Configure & order

All documents and software for this product can be found in our Download Center.

Show all downloads
Application
Technical specifications
Documentation
Accessories
Configure product

Other applications

Storage container for yeast

Pressure measurement and point level detection in the storage container

Pressure measurement and point level detection in the storage container

To the application

Condenser

Condenser pressure and point level measurement.

Condenser pressure and point level measurement.

To the application

Fermentation tank

Level, pressure and point level measurement in the fermentation tank

Level, pressure and point level measurement in the fermentation tank

To the application

Mixer

Mixer

Point level detection in the mixer

To the application
Technical specifications
Measuring range - Distance
  • - [Meter - Foot]
Process temperature
  • -40 ... 115 °C [°C - °F]
Process pressure
  • -1 ... 64 bar [Bar - kPa - psi]
Materials, wetted parts
  • 316L
  • PEEK
Threaded connection
  • ≥ G½, ≥ ½ NPT
Hygenic fittings
  • Clamp ≥ 2", DN50 - DIN32676, ISO2852
  • Clamp ≥ 1" - DIN32676, ISO2852
  • Clamp ≥ 1½" - DIN32676, ISO2852
  • Slotted nut ≥ 1½", ≥ DN40 - DIN 11851
  • Slotted nut ≥ DN25 - DIN 11851
  • Slotted nut ≥ DN32 - DIN 11851
Seal material
  • EPDM
  • FKM
Protection rating
  • IP66/IP67
  • IP69
Output
  • Transistor (NPN/PNP)
  • IO-Link
Ambient temperature
  • -40 ... 70 °C
Approvals
Scope
  • ATEX / Europe
  • IEC / worldwide
  • KOSHA / Korea
  • NEPSI / China
  • UKR Sepro / Ukraine
  • INMETRO / Brazil
  • KTL Korea
  • CSA / USA and Canada
  • CCC
  • IA
  • UKEX
Explosion protection
  • Dust ignition protection "t"
  • Increased safety "e"
Foodstuffs/Pharma
  • 3A
  • EHEDG
  • FDA
  • EG1935/2004
Ship approval
  • ABS
  • BV
  • CCS
  • DNV
  • LR
  • RINA
Overfill protection
  • WHG
  • VLAREM II
Display & adjustment
Adjustment
  • Smartphone / Tablet / PC via Bluetooth
  • PC, PACTware and DTM, IODD
Indication
  • 360° status display

Drawing generator

Generate 2D and 3D drawings for your specific configuration.

Configure Now

Product catalog

Capacitive

    • EN
    • DE
    • CS
    • ES
    • FR
    • IT
    • NL
    • PL
    • PT
    • TR
    • ZH
Download

Product information

VEGAPOINT 11, 21, 23, 24, 31

    • EN
    • US
    • DE
    • DA
    • ES
    • FR
    • IT
    • NL
    • PL
    • PT
    • SV
    • TR
    • ZH
Download

Specification sheet

VEGAPOINT 21

Transistor (NPN/PNP)

    • EN
    • US
    • DE
    • CS
    • DA
    • ES
    • FR
    • HU
    • IT
    • NL
    • NO
    • PL
    • PT
    • SV
    • TR
    • ZH
Download

Operating instructions

VEGAPOINT 21

Transistor (NPN/PNP)

    • EN
    • DE
    • CS
    • DA
    • ES
    • FI
    • FR
    • HU
    • IT
    • KK
    • KO
    • NL
    • NO
    • PL
    • PT
    • SV
    • TR
    • UK
    • ZH
Download

Drawing generator

Generate 2D and 3D drawings for your specific configuration.

Configure Now

Further downloads for this product

All documents and software for this product can be found in our Download Center.

Show all downloads
Adapters and sockets
Accessory

Hygienic adapter for G½"

$ 48.50

Base price

Show Product

Hygienic adapter for G1" sealing with O-ring

$ 48.50

Base price

Show Product

Hygienic adapter for G1" metallically sealing

$ 48.50

Base price

Show Product

Welded socket VEGAPOINT

$ 22.70

Base price

Show Product

M12 connection cables

$ 18.20

Base price

Show Product

M12 connection cable single-sided

Mounting bracket

For wall mounting of VEGA instruments.

Show Product
Loading device data
Configuration is being created
Loading configuration
Want to pick up where you left off?
Your latest configuration
{{lastConfiguration.code}}
{{getLastConfigurationDate()}}
Open configuration
An error occured while sending the last request. Please try again. ({{httpErrorStatusCode}})

An error has occurred

An error occurred when starting the configurator. We have documented the error and are working on it.
Please try again later. Alternatively you can contact us directly.

Thank you very much for your understanding.

Settings

VEGAPOINT 21

{{subGroup.subGroupName}}
Go to: {{activeGroup.nextGroup.groupName}}

Close