Level measurement in the raw water basin
Water treatment
|
|
Process data
Measuring task:
Level measurement
Measuring point:
Open basin
Measuring range up to:
3 m
Medium:
Raw water
Process temperature:
+10 … +30 °C
Process pressure:
0 … 0 bar
Special challenges:
Contaminants and abrasion
Application
The raw water facility, is extracted mostly from rivers, it is conditioned for use in the steam and condensate loops. Reliable level measurement in the raw water basin ensures that there is always an adequate supply of water.
Your benefit
Reliable
Reliable measurement of the level
Cost effective
Maintenance-free operation of the measuring point
User friendly
Simple installation and adjustment
Recommended products
Solution 1
Solution 2
VEGAPULS C 21
Radar sensor for gauge measurement
- Maintenance-free operation through non-contact 80 GHz radar technology
- Highly resistant materials ensure a long service life and maintenance-free operation
- Secure wireless operation via Bluetooth with smartphone, tablet or PC
Measuring range - Distance
15 m
Process temperature
-40 ... 80 °C
Process pressure
-1 ... 3 bar
VEGAWELL 52
Hydrostatic level measurement in the raw water basin ensures an adequate supply of water
- Robust, maintenance-free measurement
- High measurement certainty, even with heavy foam generation
- Wear-free and abrasion resistant ceramic measuring cell
Measuring range - Pressure
0 ... 60 bar
Process temperature
-20 ... 80 °C
Process pressure
-
Close