Steam pipe
Condensate detection in the water-steam cycle
|
|
Process data
Measuring task:
Point level detection
Measuring point:
Closed pipe system
Measuring range up to:
Switching contact
Medium:
Steam/condensate
Process temperature:
+150 … +320 °C
Process pressure:
+60 … +100 bar
Special challenges:
High pressures and temperatures
Application
To warm up the water for the boiler, steam is bled from the power plant turbine and delivered into a preheater. As the steam cools and condenses, it is removed from the preheater with pumps. Any condensate gathering in steam pipes has to be reliably detected to prevent it from entering the turbine. Vibrating level switches, mounted at low points in the system, reliably detect any water accumulation.
Your benefit
Reliable
Optimum protection of the turbine against condensation
Cost effective
Simple mounting and dependable function
User friendly
Function test via test button
Recommended products
VEGASWING 66
Vibrating level switch for point level detection in the steam line
- High security through self-monitoring of sensor and electronics at extreme process temperatures and pressures
- Fast and reliable function test via the press of a button
- Flexible and trustworthy in applications up to SIL3
Process temperature
-196 ... 450 °C
Process pressure
-1 ... 160 bar
Version
Compact version
with gas-tight leadthrough
with tube extension
Close