Shaker
Level measurement and point level detection in the shaker
Process data
Measuring task:
Level measurement and point level detection
Measuring point:
Vessel
Measuring range up to:
2 m
Medium:
Drilled rock, sand, mud (drilling mud)
Process temperature:
0 …+80 °C
Process pressure:
0 … 0 bar
Special challenges:
Strong vibration, buildup
Application
Through the effects of strong vibration in the shaker, the liquid and solid components of the drilling mud returning from the borehole are separated from each other. The drilled rock and the sand are disposed of and the valuable drilling mud is fed back into the continuous drilling process. Level measurement and point level detection are absolutely necessary for effective processing of the drilling mud in the shaker.
Your benefit
Reliable
Reliable measurement, independent of the process conditions
Cost effective
Ensures effective processing of the drilling mud
User friendly
Simple installation and setup from above
Recommended products
VEGAPULS 6X
Non-contact level measurement with radar in the shaker
- Accurate measurement, independent of media properties
- Reliable measurement, unaffected by vibration and buildup
- High equipment availability, as wear and maintenance-free
Measuring range - Distance
120 m
Process temperature
-196 ... 450 °C
Process pressure
-1 ... 160 bar
VEGACAP 65
Capacitive level switch for point level detection in the shaker
- Long service life thanks to robust mechanical construction
- Reliable switching point ensured by large gravity weight
- Maintenance-free operation, as non-sensitive to soiling
Measuring range - Distance
-
Process temperature
-50 ... 200 °C
Process pressure
-1 ... 64 bar
Close