Pulper
Level measurement and blockage detection in the pulper and conveyor belt monitoring
|
|
Process data
Measuring task:
Level measurement and blockage detection
Measuring point:
Pulper, conveyor belt
Measuring range up to:
4 m
Medium:
Waste paper/pulp
Process temperature:
+20 … +40 °C
Process pressure:
0 … 0 bar
Special challenges:
Pressure surges, abrasion, vortex formation
Application
Waste paper or pulp bales are transported on a conveyor belt to the pulper, where they are broken down by adding process water. A stirrer speeds up to separate fibers. Difficult process conditions exist in the pulper: falling bales cause severe pressure shocks, the stirrer creates vortexes. Besides that, foreign substances like wire, glass or sand enter the process along with the waste paper and have an extremely abrasive effect on the interior of the vessel. To ensure an automatic process flow, the level measuring system must establish the ratio of waste paper/pulp to process water. In addition, a possible jamming of the bales on the conveyor belt must be detected.
Your benefit
Reliable
Prevents jamming, thus ensuring a smooth automated process
Cost effective
Enables optimal ratio of pulp/waste paper to process water
User friendly
Wear and maintenance-free thanks to non-contact measurement
Recommended products
VEGAMIP 61
Microwave barrier for measurement of the loading height
- Non-contact measurement, therefore wear-free
- Reliable measurement of loading height
- Maintenance-free detection system, no cleaning required
Measuring range - Distance
100 m
Process temperature
-40 ... 80 °C
Process pressure
-1 ... 4 bar
VEGABAR 82
Hydrostatic level measurement in the pulper
- Highly resistant to overload from pressure surges
- Very highly abrasion resistant
- Wear-free ceramic measuring cell for a long service life
Measuring range - Distance
-
Measuring range - Pressure
-1 ... 100 bar
Process temperature
-40 ... 150 °C
Close