VEGAPULS C 22

Wired radar sensor for continuous level measurement

For standard measuring tasks, IP66/IP68, Type 6P


Application area

Lateral cable outlet, measuring range up to 20 m, accuracy ±2 mm, 4 ... 20 mA, HART, SDI-12 or Modbus output, Ex approval optional
VEGAPULS C 22 is the ideal sensor for non-contact level measurement in simple applications where a high degree of protection is required. It is particularly suitable for use in water treatment, pumping stations and rain overflow basins, for flow measurement in open channels and level monitoring. In bulk solids the sensors are used in small bulk solids silos or open containers.

Your benefit

  • Exact measurement results independent of medium, process and environmental conditions
  • Low overall height and reliable measurement even in case of flooding
  • Maintenance-free operation due to non-contact 80 GHz radar technology

Suitable accessories

Mounting bracket with adjustable sensor holder

Mounting bracket for ceiling mounting

Mounting angle with adjustable bracket

Further accessories

Base price

AU$ 1,300.00

Detailed information on prices and delivery times can be found in the Configurator.

Staggered Prices

Quantity Price
from 1 AU$ 1,300.00
from 5 10 % Discount
from 10 Please contact us!
Configure & order

All documents and software for this product can be found in our Download Center.

Show all downloads
Application
Technical specifications
Documentation
Accessories
Configure product

Other applications

Fish farming tank

Fish farming tank

Level measurement in fish farming tanks

To the application

Pure water tank

Level measurement in the pure water tank

Level measurement in the pure water tank

To the application

Elevated storage tanks

Level measurement in the elevated tank

Level measurement in the elevated tank

To the application

Combined Sewer Overflow (CSO)

Füllstandmessung im Regenüberlaufbecken

Level measurement in the stormwater overflow chamber

To the application
Technical specifications
Measuring range - Distance
  • 20 m [Meter - Foot]
Process temperature
  • -40 ... 80 °C [°C - °F]
Process pressure
  • -1 ... 3 bar [Bar - kPa - psi]
Accuracy
  • ± 2 mm
Frequency
  • 80 GHz
Beam angle
Materials, wetted parts
  • PVDF
Threaded connection
  • G1½, 1½ NPT, R1½
Seal material
  • FKM
Housing material
  • Housing material
Protection rating
  • IP66/IP68 (3 bar), Type 6P
Output
  • 4 … 20 mA/HART
  • Modbus
  • SDI-12
Ambient temperature
  • -40 ... 80 °C
Approvals
Scope
  • ATEX / Europe
  • IEC / worldwide
  • NEPSI / China
  • UKR Sepro / Ukraine
  • INMETRO / Brazil
  • CCOE / India
  • KTL Korea
  • CSA / USA and Canada
  • FM / USA and Candada
  • TIIS / Japan
  • IA
  • UKEX
Explosion protection
  • Intrinsic safety "i"
  • Dust ignition protection "t"
  • Encapsulation "m"
Foodstuffs/Pharma
  • FDA
Ship approval
  • ABS
  • CCS
  • GL
  • LR
  • NK
  • RINA
Overfill protection
  • WHG
  • VLAREM II
Display & adjustment
Adjustment
  • PC, PACTware and DTM
  • Smartphone / Tablet / PC via Bluetooth

Drawing generator

Generate 2D and 3D drawings for your specific configuration.

Configure Now

Product catalog

Radar

    • EN
    • DE
    • CS
    • ES
    • FR
    • IT
    • NL
    • PL
    • PT
    • TR
    • ZH
Download

Product information

VEGAPULS C 11, C 21, C 22, C 23, 11, 21, 31

    • EN
    • US
    • DE
    • DA
    • ES
    • FR
    • IT
    • NL
    • PL
    • PT
    • SV
    • TR
    • ZH
Download

Specification sheet

VEGAPULS C 22

Two-wire: 4 … 20 mA/HART

    • EN
    • US
    • DE
    • CS
    • DA
    • ES
    • FI
    • FR
    • HU
    • IT
    • KK
    • KO
    • NL
    • NO
    • PL
    • PT
    • SV
    • TR
    • UK
    • ZH
Download

Operating instructions

VEGAPULS C 22

Two-wire: 4 … 20 mA/HART

    • EN
    • DE
    • CS
    • DA
    • ES
    • FI
    • FR
    • HU
    • IT
    • KK
    • KO
    • NL
    • NO
    • PL
    • PT
    • SV
    • TR
    • UK
    • ZH
Download

Drawing generator

Generate 2D and 3D drawings for your specific configuration.

Configure Now

Further downloads for this product

All documents and software for this product can be found in our Download Center.

Show all downloads
Controllers
Indicating instruments
Wireless communication
Separating instruments
Accessory

VEGAMET 141

1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation

AU$ 720.00

Base price

Show Product

VEGAMET 142

2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation

AU$ 940.00

Base price

Show Product

VEGAMET 341

1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation

AU$ 790.00

Base price

Show Product

VEGAMET 342

2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation

AU$ 1,000.00

Base price

Show Product

VEGAMET 841

1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation

AU$ 850.00

Base price

Show Product

VEGAMET 842

2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation

AU$ 1,070.00

Base price

Show Product

VEGAMET 861

1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation

AU$ 1,190.00

Base price

Show Product

VEGAMET 862

2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation

AU$ 1,430.00

Base price

Show Product

VEGAMET 391

VEGAMET391 Auswertgeraet und Anzeigeinstrument fuer Fuellstandsensoren

Measured value indication, simple control functions, remote enquiry of measured data. optimized for water/sewage water industry

Show Product

VEGATOR 141

Single channel signal conditioning instrument for level detection - 4 … 20 mA

Transmission of 4 ... 20 mA signals for level signalling

AU$ 410.00

Base price

Show Product

VEGATOR 142

Double channel signal conditioning instrument for level detection - 4 … 20 mA

Transmission of 4 ... 20 mA signals for level signalling

AU$ 580.00

Base price

Show Product

VEGADIS 82

External measured value display and adjustment for 4 ... 20 mA/HART sensors

AU$ 430.00

Base price

Show Product

VEGADIS 176

Remote display for use in 4 ... 20 mA current loop

AU$ 390.00

Base price

Show Product

VEGAMET 841

1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation

AU$ 850.00

Base price

Show Product

VEGAMET 842

2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation

AU$ 1,070.00

Base price

Show Product

VEGAMET 861

1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation

AU$ 1,190.00

Base price

Show Product

VEGAMET 862

2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation

AU$ 1,430.00

Base price

Show Product

PLICSMOBILE T81

externe-GSM-GPRS-Funkeinheit

Measured data enquiry and remote parameter adjustment for a HART sensor

Show Product

VEGATRENN 141

Einkanaliger Speisetrenner für 4 … 20 m/HART-Sensoren

Single channel separator for 4 … 20 m/HART sensors

AU$ 270.00

Base price

Show Product

VEGATRENN 142

Zweikanaliger Speisetrenner für 4 … 20 m/HART-Sensoren

Double channel separator for 4 … 20 m/HART sensors

AU$ 400.00

Base price

Show Product

VEGATRENN 151

Einkanaliger Trennübertrager in Zweileitertechnik für 4 … 20 mA-Sensoren

Single channel separator in two-wire technology for 4 … 20 mA sensors

AU$ 240.00

Base price

Show Product

VEGATRENN 152

Zweikanaliger Trennübertrager in Zweileitertechnik für 4 … 20 mA-Sensoren

Double channel separator in two-wire technology for 4 … 20 mA sensors

AU$ 350.00

Base price

Show Product

Mounting bracket with adjustable sensor holder

AU$ 140.00

Base price

Show Product

Mounting bracket for ceiling mounting

AU$ 60.00

Base price

Show Product

Mounting bracket for plastic vessel

AU$ 140.00

Base price

Show Product

Mounting angle with adjustable bracket

AU$ 240.00

Base price

Show Product

Mounting bracket 200 mm with fixed sensor holder

AU$ 120.00

Base price

Show Product

Hygienic adapter (G1½“) suitable for VEGAPULS 11, 21, 31, VEGAPULS C 11, C 21, C 22 and VEGAPULS Air 41

No image available

AU$ 170.00

Base price

Show Product

Threaded adapter 2" to 1½" suitable for VEGAPULS 11, 21, 31, VEGAPULS C 11, C 21, C 22 and VEGAPULS Air 41

AU$ 150.00

Base price

Show Product

Counter nut

Universal flange for VEGAPULS BASIC line

AU$ 160.00

Base price

Show Product

Alignment device for vessel wall mounting for radar sensors with 1½" thread

AU$ 250.00

Base price

Show Product
Loading device data
Configuration is being created
Loading configuration
Want to pick up where you left off?
Your latest configuration
{{lastConfiguration.code}}
{{getLastConfigurationDate()}}
Open configuration
An error occured while sending the last request. Please try again. ({{httpErrorStatusCode}})

An error has occurred

An error occurred when starting the configurator. We have documented the error and are working on it.
Please try again later. Alternatively you can contact us directly.

Thank you very much for your understanding.

Settings

VEGAPULS C 22

{{subGroup.subGroupName}}
Go to: {{activeGroup.nextGroup.groupName}}

Close