Buffer tank for potash lye
Level measurement in the buffer tank for potash lye
|
|
Process data
Measuring task:
Measuring task
Measuring point:
Level measurement
Measuring range up to:
3 m
Medium:
Potash lye
Process temperature:
-40 … +50 °C
Process pressure:
0 … 0 bar
Special challenges:
Aggressive medium
Application
Buffer tanks ensure the supply of material for the ongoing electrolysis process. The operator of the electrolysis facility needs the exact level values at all times in order to ensure timely replenishment and enable continuous and efficient hydrogen production. In addition, the measured values are used for statistical evaluation of consumption and serve as the basis for plausibility and quality monitoring.
Your benefit
Reliable
Reliable measurement ensures continuous operation of the facility
Cost effective
Long service life thanks to high chemical resistance
User friendly
Simple setup and maintenance-free in operation
Recommended products
VEGAPULS 31
Continuous level measurement with radar in the buffer tank for potash lye
- High chemical resistance through use of PTFE antenna cover
- Reliable measurement even with changing media
- Maintenance-free thanks to non-contact measurement
Measuring range - Distance
15 m
Process temperature
-40 ... 80 °C
Process pressure
-1 ... 3 bar
Close