VEGAPULS 11
Compact radar sensor for continuous level measurement
For simple measuring tasks, plastic housing IP66/IP67, Type 4X
Application area
Your benefit
- High plant availability through non-contact measurement
- Exact measurement results independent of medium properties and process conditions
- Maintenance-free operation due to non-contact 80 GHz radar technology
Suitable accessories
Mounting bracket with adjustable sensor holder |
|
Mounting angle with adjustable bracket |
|
Universal flange for VEGAPULS BASIC line |
|
Further accessories |
Configure product
Product comparison
All documents and software for this product can be found in our Download Center.
Show all downloadsOther applications
- 8 m [Meter - Foot]
- -40 ... 60 °C [°C - °F]
- -1 ... 3 bar [Bar - kPa - psi]
- ± 5 mm / ± 0.2"
- 80 GHz
- 8°
- PVDF
- G1½, 1½ NPT, R1½
- FKM
- Plastic
- IP66/IP67, Type 4X
- 4 … 20 mA
- -40 ... 60 °C
- PC, PACTware and DTM
- Smartphone / Tablet / PC via Bluetooth
Drawing generator
Generate 2D and 3D drawings for your specific configuration.
Configure NowProduct catalog
Radar
Product information
VEGAPULS C 11, C 21, C 22, C 23, 11, 21, 31
Specification sheet
VEGAPULS 11
4 … 20 mA - two-wire
Operating instructions
VEGAPULS 11
4 … 20 mA - two-wire
Drawing generator
Further downloads for this product
All documents and software for this product can be found in our Download Center.
Show all downloadsMounting bracket with adjustable sensor holder
Mounting angle with adjustable bracket
Mounting bracket 200 mm with fixed sensor holder
Hygienic adapter (G1½“) suitable for VEGAPULS 11, 21, 31, VEGAPULS C 11, C 21, C 22 and VEGAPULS Air 41
Counter nut
Universal flange for VEGAPULS BASIC line
Alignment device for vessel wall mounting for radar sensors with 1½" thread
Threaded adapter 2" to 1½" suitable for VEGAPULS 11, 21, 31, VEGAPULS C 11, C 21, C 22 and VEGAPULS Air 41
VEGAMET 141
1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 142
2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 341
1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 342
2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
Show ProductVEGAMET 841
1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 842
2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 861
1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 862
2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 391
Measured value indication, simple control functions, remote enquiry of measured data. optimized for water/sewage water industry
Show ProductVEGATOR 141
Transmission of 4 ... 20 mA signals for level signalling
Show ProductVEGATOR 142
Transmission of 4 ... 20 mA signals for level signalling
Show ProductVEGADIS 82
External measured value display and adjustment for 4 ... 20 mA/HART sensors
Show ProductVEGADIS 176
Remote display for use in 4 ... 20 mA current loop
Show ProductVEGAMET 841
1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 842
2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 861
1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGAMET 862
2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
Show ProductVEGATRENN 141
Single channel separator for 4 … 20 m/HART sensors
Show ProductVEGATRENN 142
Double channel separator for 4 … 20 m/HART sensors
Show ProductVEGATRENN 151
Single channel separator in two-wire technology for 4 … 20 mA sensors
Show ProductVEGATRENN 152
Double channel separator in two-wire technology for 4 … 20 mA sensors
Show ProductAn error has occurred
An error occurred when starting the configurator. We have documented the error and are working on it.
Please try again later. Alternatively you can contact us directly.
Thank you very much for your understanding.
VEGAPULS 11
myVEGA
With myVEGA as your personal information platform, you’ll have at your disposal numerous online functions revolving around the VEGA products.
- Configurator for the entire VEGA product range
- Information about prices and delivery times
- Order directly online
- Saving of configurations
- 2D/3D drawings of your configured instrument
- Overview of order transactions
Still no access?
Register for freeForgot password
Enter your e-mail address and we will send you a link to reset your password.
Reset password Cancel
Close