Finished product tanks
Level measurement and point level detection of finished product tanks
Process data
Measuring task:
Level measurement and point level detection
Measuring point:
Tank
Measuring range up to:
15 m
Medium:
Light or heavy hydrocarbon
Process temperature:
-40 … +50 °C
Process pressure:
0 … 0 bar
Special challenges:
Varying hydrocarbon products, possible condensation
Application
Reliable level measurement of crude and bulk liquids storage tanks in a refinery is necessary for inventory management and overspill protection. Multiple measurement devices can fit into a single process fitting.
Your benefit
Reliable
Redundant measurement ensures a high degree of safety
Cost effective
Self-monitoring reduces maintenance costs
User friendly
Easy installation and setup
Recommended products

VEGASWING 63
Vibrating level switch for overfill protection in finished product tanks
- High level switch provides redundancy
- Maximum flexibility through switching point adaptable to the application
- By simply pushing a button, you can meet the requirements of WHG and SIL of the periodic test
- Unaffected by media properties ensures reliable measurement
Process temperature
-50 ... 250 °C
Process pressure
-1 ... 64 bar
Version
Standard
Hygienic applications
with gas-tight leadthrough
with tube extension
with temperature adapter

VEGAPULS 6X
Level measurement with radar in end-product tanks
- Simple retrofitting, as existing process fittings can continue to be used
- Exact measuring results regardless of temperature, gas or steam
- Certified according to SIL 2 and WHG for use as overfill protection
Measuring range - Distance
120 m
Process temperature
-196 ... 450 °C
Process pressure
-1 ... 160 bar
Close