Reaction vessel with solvents
Level and pressure measurement and point level detection in mixing processes
Process data
Application
Your benefit
Recommended products
![VEGAFLEX 83](/-/media/images/products/sensors/f-fx83-gefuehrtes-radar-tdr-vegaflex83-fuellstand-trennschicht-hygiene-flansch-kunststoff.png?mh=140&hash=F34B53E6F2B0F339373D7BBED9D641BE&mw=105)
VEGAFLEX 83
Guided radar sensor for level measurement
- Easy installation in restricted installation situations thanks to segmented rods
- Reliable measurement despite strong foam generation
- Hygienic, gap-free design ensures easy and reliable CIP and SIP cleaning
![VEGABAR 83](/-/media/images/products/sensors/f-br83-pressure-sensor-with-metallic-measuring-cell-vegabar83-flange.png?rev=90b505909ac64b02bf4bf54db1f390a0&mh=140&hash=AE38C10761052D39171C5AC266EEEF83&mw=105)
VEGABAR 83
Pressure transmitter for monitoring pressure
- Unaffected by internal fixtures such as agitators or heating coils
- Unaffected by foaming
![VEGASWING 61 Vibrating level switch for liquids](/-/media/images/products/sensors/f-swing61-vibrationsgrenzschalter-vegaswing61-gewinde.png?rev=f62fcbd87fbf4438a2734ea19a46d768&mh=140&hash=29D78FAB762442B13E8477E2DB6BF894&mw=105)
VEGASWING 61
Vibrating level switch for point level detection
- Reliable measurement, independent of process parameters
- Adaptable to any medium through special coatings, e.g. glass and polymer
![VEGAPULS 6X](/-/media/images/products/sensors/f-ps6x-vegapuls-6x-radar-level-sensor-for-hygienic-requirements.png?mw=105&hash=8284D0DCA6D7CBC196A5E77DD7BBEDB9)
VEGAPULS 6X
Non-contact level measurement with Radar
- Reliable level measurement, independent of process conditions such as temperature, changing product density and condensate
- Focusing of the sensor allows accurate measurement despite stirrers
![VEGABAR 83](/-/media/images/products/sensors/f-br83-pressure-sensor-with-metallic-measuring-cell-vegabar83-flange.png?rev=90b505909ac64b02bf4bf54db1f390a0&mh=140&hash=AE38C10761052D39171C5AC266EEEF83&mw=105)
VEGABAR 83
Pressure transmitter for monitoring pressure
- Unaffected by internal fixtures such as agitators or heating coils
- Unaffected by foaming
![VEGASWING 61 Vibrating level switch for liquids](/-/media/images/products/sensors/f-swing61-vibrationsgrenzschalter-vegaswing61-gewinde.png?rev=f62fcbd87fbf4438a2734ea19a46d768&mh=140&hash=29D78FAB762442B13E8477E2DB6BF894&mw=105)
VEGASWING 61
Vibrating level switch for point level detection
- Reliable measurement, independent of process parameters
- Adaptable to any medium through special coatings, e.g. glass and polymer