VEGAPULS 61

Radar sensor for continuous level measurement of liquids

For simple process conditions


with encapsulated horn antenna (ø40 mm)
with plastic horn antenna (ø80 mm)

Application area

Simple, versatile mounting options for the plastic antenna using flange or mounting bracket offer an economical solution.
The VEGAPULS 61 is a radar sensor for continuous level measurement of liquids under simple process conditions. The VEGAPULS 61 is an economical solution through its simple and versatile mounting possibilities. The encapsulated antenna system ensures a maintenance-free operation.

Your benefit

  • Exact measuring results independent of process conditions
  • High plant availability, because wear and maintenance-free
  • Maintenance-free operation through non-contact measuring principle

Newer product available

There is a successor for this product. If you have any questions about the product, please contact your VEGA representative.

VEGAPULS 6X

Configure product

Configure product

All documents and software for this product can be found in our Download Center.

Show all downloads
Application
Technical specifications
Documentation
Accessories
Configure product

Continuous level measurement of liquids – the reliable solution for simple applications

The radar gauge VEGAPULS 61 is in use everywhere where the level of liquids in tanks has to be measured continuously and contactlessly. Application possibilities for radar gauges can be found in almost all areas of industry. Sewage treatment plants and water purification plants in particular, but also other environmental engineering facilities as well as power generating stations now rely on cost-effective radar sensors for continuous level measurement.
Technical specifications
Measuring range - Distance
  • 35 m [Meter - Foot]
Process temperature
  • -40 ... 80 °C [°C - °F]
Process pressure
  • -1 ... 3 bar [Bar - kPa - psi]
Accuracy
  • ± 2 mm
Frequency
  • 26 GHz
Beam angle
  • ≥ 10°
Version
  • with plastic horn antenna ø 80 mm
  • Encapsulated horn antenna
Materials, wetted parts
  • PVDF
  • 316L
  • PP
Threaded connection
  • G1½, 1½ NPT
Flange connection
  • ≥ DN80, ≥ 3"
Hygenic fittings
  • Clamp ≥ 2", DN50 - DIN32676, ISO2852
  • Slotted nut ≥ 2", DN50 - DIN 11851
Housing material
  • Plastic
  • Aluminium
  • Stainless steel (precision casting)
  • Stainless steel (electropolished)
Protection rating
  • IP66/IP68 (0,2 bar)
  • IP66/IP67
  • IP66/IP68 (1 bar)
Output
  • Profibus PA
  • Foundation Fieldbus
  • Two-wire: 4 … 20 mA/HART
  • Modbus
  • Four-wire: 4 … 20 mA/HART
Ambient temperature
  • -40 ... 80 °C
Approvals
Scope
  • ATEX / Europe
  • CSA / Canada
  • FM / USA
  • EAC (GOST) / Belarus
  • EAC (GOST) / Kazakhstan
  • EAC (GOST) / Russia
  • IEC / worldwide
  • KOSHA / Korea
  • NEPSI / China
  • UKR Sepro / Ukraine
  • IEC / Australia
  • UKEX
Explosion protection
  • Intrinsic safety "i"
  • Flameproof enclosure "d"
Ship approval
  • ABS
  • BV
  • CCS
  • DNV
  • LR
  • NK
  • RINA
  • RMROS
Overfill protection
  • WHG
SIL qualification
  • SIL2
Display & adjustment
Adjustment
  • PLICSCOM
  • PC, PACTware and DTM
  • HART-Communicator
  • Software (e. g. AMS™, PDM)
Indication
  • Display/adjustment module PLICSCOM
  • VEGADIS 81
  • Pluggable display module PLICSLED
  • VEGADIS 82

Drawing generator

Generate 2D and 3D drawings for your specific configuration.

Configure Now

Product information

VEGAPULS WL 61, 61, 62, 63, 64, 65, 66

    • EN
    • US
    • DE
    • ES
    • FR
    • IT
    • NL
    • PT
    • TR
    • ZH
Download

Specification sheet

VEGAPULS 61

Two-wire: 4 … 20 mA/HART

    • EN
    • US
    • DE
    • ES
    • FR
    • IT
    • NL
    • PT
    • TR
    • ZH
Download

Operating instructions

VEGAPULS 61

Two-wire: 4 … 20 mA/HART

Sensor

    • EN
    • DE
    • CS
    • ES
    • FR
    • HU
    • IT
    • KK
    • NL
    • PL
    • PT
    • TR
    • UK
    • ZH
Download

Drawing generator

Generate 2D and 3D drawings for your specific configuration.

Configure Now

Further downloads for this product

All documents and software for this product can be found in our Download Center.

Show all downloads
Indicating instruments
Controllers
Wireless communication
Separating instruments
Overvoltage protection instruments
Components
Accessory
Spare parts
Our recommendation

PLICSCOM

PLICSCOM Steckbares Anzeige- und Bedienmodul

Measured value indication and adjustment of plics® sensors

Show Product

Bluetooth USB adapter

Wireless adjustment of sensors and instruments via Bluetooth

Show Product

VEGADIS 81

Remote measurement value indication and adjustment of plics® sensors

kr. 2,351.00

Base price

Show Product

VEGADIS 82

External measured value display and adjustment for 4 ... 20 mA/HART sensors

kr. 1,881.00

Base price

Show Product

VEGADIS 176

Remote display for use in 4 ... 20 mA current loop

kr. 1,694.00

Base price

Show Product

Magnetic pen for display/adjustment module PLICSCOM

PLICSCOM Magnet Pen

Magnetic pen for on-site adjustment

Show Product

VEGAMET 141

1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation

kr. 3,179.00

Base price

Show Product

VEGAMET 142

2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation

kr. 4,119.00

Base price

Show Product

VEGAMET 341

1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation

kr. 3,455.00

Base price

Show Product

VEGAMET 342

2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation

kr. 4,396.00

Base price

Show Product

VEGAMET 841

1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation

kr. 3,739.00

Base price

Show Product

VEGAMET 842

2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation

kr. 4,679.00

Base price

Show Product

VEGAMET 861

1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation

kr. 5,200.00

Base price

Show Product

VEGAMET 862

2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation

kr. 6,300.00

Base price

Show Product

VEGAMET 624

VEGAMET625 Auswertgeraet und Anzeigeinstrument fuer Fuellstandsensoren.png	352 KB		 VEGAMET624 Auswertgeraet und Anzeigeinstrument fuer Fuellstandsensoren

Measured value indication, simple control functions such as remote enquiry of measured values for a 4 ... 20 mA/HART sensor

Show Product

VEGAMET 625

VEGAMET625 Auswertgeraet und Anzeigeinstrument fuer Fuellstandsensoren

Measured value indication, simple control functions such as remote enquiry of measured values for two HART sensors

Show Product

VEGAMET 391

VEGAMET391 Auswertgeraet und Anzeigeinstrument fuer Fuellstandsensoren

Measured value indication, simple control functions, remote enquiry of measured data. optimized for water/sewage water industry

Show Product

VEGATOR 141

Single channel signal conditioning instrument for level detection - 4 … 20 mA

Transmission of 4 ... 20 mA signals for level signalling

kr. 1,791.00

Base price

Show Product

VEGATOR 142

Double channel signal conditioning instrument for level detection - 4 … 20 mA

Transmission of 4 ... 20 mA signals for level signalling

kr. 2,552.00

Base price

Show Product

VEGASCAN 693

Signal conditioning instrument for up to 15 HART sensors

Measured value indication and remote enquiry of measured data for up to 15 HART sensors

Show Product

PLICSMOBILE T81

externe-GSM-GPRS-Funkeinheit

Measured data enquiry and remote parameter adjustment for a HART sensor

Show Product

VEGATRENN 141

Einkanaliger Speisetrenner für 4 … 20 m/HART-Sensoren

Single channel separator for 4 … 20 m/HART sensors

kr. 1,179.00

Base price

Show Product

VEGATRENN 142

Zweikanaliger Speisetrenner für 4 … 20 m/HART-Sensoren

Double channel separator for 4 … 20 m/HART sensors

kr. 1,746.00

Base price

Show Product

VEGATRENN 151

Einkanaliger Trennübertrager in Zweileitertechnik für 4 … 20 mA-Sensoren

Single channel separator in two-wire technology for 4 … 20 mA sensors

kr. 1,037.00

Base price

Show Product

VEGATRENN 152

Zweikanaliger Trennübertrager in Zweileitertechnik für 4 … 20 mA-Sensoren

Double channel separator in two-wire technology for 4 … 20 mA sensors

kr. 1,515.00

Base price

Show Product

Overvoltage protection B 81-35

Pluggable overvoltage protection for supply and signal cables

kr. 642.00

Base price

Show Product

Overvoltage protection B 63-32

Überspannungsschutz B63

Overvoltage protection for Profibus PA and Foundation Fieldbus circuits

kr. 1,299.00

Base price

Show Product

Overvoltage protection B 63-48

Ueberspannungsschutz-B63

Overvoltage protection for two-wire circuits

kr. 1,201.00

Base price

Show Product

Overvoltage protection B 62-30 W

Ueberspannungsschutz B62-30W in Zweileitertechnik Profibus-PA Foundation-Fieldbus-Stromkreise

Overvoltage protection for Profibus PA and Foundation Fieldbus circuits

kr. 925.00

Base price

Show Product

Overvoltage protection B 62-36 G

Ueberspannungsschutz B62-30G Versorgungs- und Signalleitungen in 4-20 mA-Stromkreisen

Overvoltage protection for two-wire circuits

kr. 828.00

Base price

Show Product

VEGACONNECT

Interface adapter between PC and VEGA instruments

Show Product

VEGABOX 03

Druckausgleichsgehäuse mit Belüftungsfilter

Breather housing with ventilation filter

Show Product

Profibus PA/DP segment coupler

Simple segment coupler for up to 93.75 kbit/s DP-side

Show Product

Adapter flanges VEGAPULS 6X / 61 / 67 / 69 / 64

The adapter flange is a retrofitting part for these radar sensors for connection to flanges on the plant side

Show Product

Rinsing connection VEGAPULS 61, 64, 67, 69

The rinsing connection is an accessory part for VEGAPULS WL 61, 61, 67 and 69 radar sensors.

Show Product

Mounting strap

For mounting of VEGA instruments.

Show Product

Mounting bracket with 45° reflector

For mounting of radar sensors VEGAPULS 61 and VEGAPULS WL 61.

Show Product

Protective cover

The protective cover is an accessory or retrofit part for sensors from the VEGA plics® line of products.

Show Product

Antenna extension PLICSMOBILE

VEGADIS adapter

102410-Adapter-VEGADIS81-or-BAR-Slave

For connection of an external display and adjustment unit or a Secondary sensor.

Show Product

Electronics VEGAPULS series 60 plics®plus

Electronics VEGAPULS series 60 plics®

Process component VEGAPULS 61

Remote housing PLICS

Remote housing - Plastic

Replacement housing for plics® instruments

Show Product

Single chamber housing PLICS

Single chamber housing - Plastic

The housing is a spare oart for sensors of the plics® family

Show Product

Double chamber housing PLICS

Double chamber housing - Plastic

The housing is a spare oart for sensors of the plics® family

Show Product

Housing cover PLICS

Plug connection PLICS

The plug connector is an accessory part for sensors with single or double chamber housing. It is used as separable connection to power supply or signal processing.

Show Product

PLICSMOBILE plug connector with SMA connection

Electronics PLICSMOBILE series 80

Loading device data
Configuration is being created
Loading configuration
Want to pick up where you left off?
Your latest configuration
{{lastConfiguration.code}}
{{getLastConfigurationDate()}}
Open configuration
An error occured while sending the last request. Please try again. ({{httpErrorStatusCode}})

An error has occurred

An error occurred when starting the configurator. We have documented the error and are working on it.
Please try again later. Alternatively you can contact us directly.

Thank you very much for your understanding.

Settings

VEGAPULS 61

{{subGroup.subGroupName}}
Go to: {{activeGroup.nextGroup.groupName}}

Close