Seawater extraction
Level measurement for seawater extraction
|
|
Process data
Measuring task:
Level measurement
Measuring point:
Open basin
Measuring range up to:
5 m
Medium:
Salt water
Process temperature:
0 ... +40 °C
Process pressure:
0 ... 0 bar
Special challenges:
Environmental influences from rain, wind and sun
Application
The seawater is fed into large buffer basins for further processing, sometimes these can be several hundred metres from the coast. Level measurement in the basins controls the extraction pumps and thus enables reliable operation of the plant.
Your benefit
Reliable measurement
Accurate data under all environmental conditions
Cost effective
Maintenance-free operation
User friendly
Simple mounting and setup
Recommended products
VEGAPULS C 21
Radar sensor for level measurement in open basins
- Exact measuring results unaffected by ambient conditions
- High plant availability thanks to wear and maintenance free measurement
- Secure wireless operation via Bluetooth with smartphone, tablet or PC
Measuring range - Distance
15 m
Process temperature
-40 ... 80 °C
Process pressure
-1 ... 3 bar
VEGAMET 841
Controller for measured value processing and display
- Universal controller for pump control and measured value display
- Analogue outputs for connection to process control systems
- Quick setup via simple menu navigation and application wizards
Protection rating
IP66/IP67, Type 4X
Input
1 x 4 … 20 mA sensor input
Output
1 x 0/4 … 20 mA current output
3 x operating relay
1x failure relay (instead of operating relay)