Separation vessel
Level measurement and point level detection in a separator vessel tank for recovery of raw materials
|
|
Process data
Measuring task:
Level and interface measurement, point level detection
Measuring point:
Vessel
Measuring range up to:
15 m
Medium:
Water-based media and hydrocarbons
Process temperature:
+20 … +80 °C
Process pressure:
0 … +16 bar
Special challenges:
Alternating media properties, emulsions
Application
These processes often involve the separation of water-based media from hydrocarbons. In most applications, the upper, lighter medium is electrically non-conductive. Guided radar level measurement makes use of the effect that non-conductive media allow some of the radar energy to pass through, thus enabling a measurement of the interface between the water-based lower medium and the hydrocarbons.
Your benefit
Reliable
Reliable measurement of the interface (separation layer)
Cost effective
Maintenance-free operation
User friendly
Easy setup and commissioning
Recommended products
VEGAFLEX 81
Level and interface measurement with guided radar in the separation tank
- Total level and position of the interface are reliably detected with a rod or coaxial sensor
- Separation layer thicknesses from 50 mm can be measured
- VEGAFLEX 81 measures reliably and accurately, even in emulsion phases
- Simple setup and maintenance-free operation
Measuring range - Distance
75 m
Process temperature
-60 ... 200 °C
Process pressure
-1 ... 40 bar
VEGACAP 63
Capacitive level switch for conductive liquids for level measurement in the separation tank
- Reliable differentiation between conductive and non-conductive media
- Reliable level measurement of the separated water quantity for disposal
- Simple mounting and calibration
Measuring range - Distance
-
Process temperature
-50 ... 200 °C
Process pressure
-1 ... 64 bar