Ice cream "Premix" mixer
Level and pressure measurement during the mixing of ice cream ingredients
Process data
Measuring task:
Level and pressure measurement
Measuring point:
Tank/pipe
Measuring range up to:
1.5 m
Medium:
Ice cream
Process temperature:
0 … +125 °C
Process pressure:
-1 … +5 bar
Special challenges:
Large temperature fluctuations, condensate
Application
The ingredients for making ice cream are accurately weighed and fed into a mixing tank, where the "premix" is made. Afterwards, the premix is passed through the homogenizer at a pressure of about 140 bar and then pasteurized at 80 °C. The level in the premix vessel and the pressure in the pipeline leading to the homogenizer need to be continuously monitored to ensure continuous ice cream production.
Your benefit
Reliable
Certified materials according to FDA and EC 1935/2004 regulations
Cost effective
Short delivery time and standardized operation thanks to plics® concept
User friendly
Simple installation due to small dimensions
Recommended products
VEGAPULS 42
Continuous level measurement with radar in the “premix“
- Non-contact measurement, independent of agitators due to tight focussing, even in the smallest of containers
- Compact design allows installation even in very small vessels
- Reliable measurement, immune to the formation of condensation
Measuring range - Distance
15 m
Process temperature
-40 ... 130 °C
Process pressure
-1 ... 16 bar
VEGABAR 83
Pressure transmitter for monitoring pressure in a homogenizer
- Robust diaphragm easily handles high pressures
- Resistant to vacuum during the cleaning cycle
Measuring range - Distance
-
Measuring range - Pressure
-1 ... 1000 bar
Process temperature
-40 ... 200 °C
Close