Compressor knockout drum
Level measurement in the compressor knockout drum
|
|
Process data
Measuring task:
Level measurement
Measuring point:
Tank
Measuring range up to:
2 m
Medium:
Hydrocarbon or water
Process temperature:
+60 … +120 °C
Process pressure:
+3 … +10 bar
Special challenges:
Changing medium properties
Application
The vapour liquid separation that occurs in a knockout drum protects the waste or cooling stream from process vapours and compressors from water. This crucial measurement point means it requires constant, reliable level monitoring without being influenced by the high volume of vapour inside the vessel. A reliable instrument ensures that there is no water carry-over into the compressor, avoiding the extremely expensive downtime that results from an upset.
Your benefit
Reliable
Diverse technologies with comparative output can provide redundant level measurement
Cost effective
Materials with high chemical resistance reduce maintenance costs
User friendly
Easy installation and setup
Recommended products
VEGAPULS 6X
Level measurement with radar in the compressor knockout drum
- Reliable measurement, unaffected by vapour presence
- Easy installation directly in the drum
- Unaffected by changing density
Measuring range - Distance
120 m
Process temperature
-196 ... 450 °C
Process pressure
-1 ... 160 bar
VEGABAR 82
Electronic differential pressure system for measurement redundancy in the compressor knockout drum
- No additional temperature influences because no liquid capillary connection required
- Very good reproducibility and long-term stability
- High resistance diaphragm materials
- Easy installation because no insulation for capillary needed
Measuring range - Distance
-
Measuring range - Pressure
-1 ... 100 bar
Process temperature
-40 ... 150 °C