VEGAFLEX 86
TDR sensor for continuous level and interface measurement of liquids
For the most extreme process conditions
Application area
Your benefit
- The guided adjustment enables a simple, time-saving and reliable setup
- Shortenable probes offer a simple standardisation and highest flexibility in the planning
- Comprehensive diagnostic possibilities ensure a maintenance-free operation and hence a high plant availability
Configure product
Product comparison
All documents and software for this product can be found in our Download Center.
Show all downloadsLevel and interface measurement at high pressure and high temperature
The robust guided radar sensor VEGAFLEX 86 measures the level and interface of liquids at high process temperatures and pressures in tanks of all types. It operates independently of media properties such as density or dielectric constant in widely different vessels, bypasses or boilers. The robust mechanical design and second seal (second line of defense) protect the sensor while it performs demanding measurement tasks in the chemical, petrochemical, energy and oil/gas sectors, e.g.
- level and interface measurement in distillation columns
- level measurement in steam boilers
- level measurement in gas tanks (LPG)
- 75 m [Meter - Foot]
- -196 ... 450 °C [°C - °F]
- -1 ... 400 bar [Bar - kPa - psi]
- ± 2 mm
- Coax version ø 21.3 mm with multiple hole
- Coax version ø 42.2 mm with single hole
- Coax version ø 42.2 mm with multiple hole
- Exchangeable rod ø 16 mm
- Exchangeable cable ø 2 mm with gravity weight
- Exchangeable cable ø 4 mm with gravity weight
- Exchangeable cable ø 2 mm with centering weight
- Exchangeable cable ø 4 mm with centering weight
- 316L
- Alloy C22 (2.4602)
- 316
- ≥ G¾, ≥ ¾ NPT
- ≥ DN25, ≥ 1"
- FFKM
- graphit and ceramic
- Plastic
- Aluminium
- Stainless steel (precision casting)
- Stainless steel (electropolished)
- IP66/IP68 (0,2 bar)
- IP66/IP67
- IP66/IP68 (1 bar)
- Profibus PA
- Foundation Fieldbus
- Two-wire: 4 … 20 mA/HART
- Modbus
- Four-wire: 4 … 20 mA/HART
- -40 ... 80 °C
- ATEX / Europe
- CSA / Canada
- FM / USA
- EAC (GOST) / Belarus
- EAC (GOST) / Kazakhstan
- EAC (GOST) / Russia
- IEC / worldwide
- NEPSI / China
- UKR Sepro / Ukraine
- INMETRO / Brazil
- CCOE / India
- UKEX
- Intrinsic safety "i"
- Flameproof enclosure "d"
- Dust ignition protection "t"
- ABS
- BV
- CCS
- DNV
- LR
- NK
- RINA
- WHG
- VLAREM II
- SIL2
- EN12952-11, EN12953-9
- PLICSCOM
- PC, PACTware and DTM
- HART-Communicator
- Software (e. g. AMS™, PDM)
- Display/adjustment module PLICSCOM
- VEGADIS 81
- VEGADIS 82
Drawing generator
Generate 2D and 3D drawings for your specific configuration.
Configure NowProduct catalog
Guided radar
Product information
VEGAFLEX 81, 83, 86
Product information
VEGAFLEX 82, 86
Specification sheet
VEGAFLEX 86
Two-wire: 4 … 20 mA/HART
Operating instructions
VEGAFLEX 86
Two-wire: 4 … 20 mA/HART
Drawing generator
Further downloads for this product
All documents and software for this product can be found in our Download Center.
Show all downloadsBluetooth USB adapter
Wireless adjustment of sensors and instruments via Bluetooth
Show ProductVEGADIS 81
Remote measurement value indication and adjustment of plics® sensors
R 7,090.00
VEGADIS 82
External measured value display and adjustment for 4 ... 20 mA/HART sensors
R 5,670.00
VEGADIS 176
Magnetic pen for display/adjustment module PLICSCOM
Magnetic pen for on-site adjustment
Show ProductVEGAMET 141
1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
R 9,590.00
VEGAMET 142
2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
R 12,400.00
VEGAMET 341
1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
R 10,400.00
VEGAMET 342
2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
R 13,300.00
VEGAMET 841
1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
R 11,300.00
VEGAMET 842
2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
R 14,100.00
VEGAMET 861
1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
R 15,800.00
VEGAMET 862
2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
R 18,900.00
VEGAMET 624
Measured value indication, simple control functions such as remote enquiry of measured values for a 4 ... 20 mA/HART sensor
Show ProductVEGAMET 625
Measured value indication, simple control functions such as remote enquiry of measured values for two HART sensors
Show ProductVEGAMET 391
Measured value indication, simple control functions, remote enquiry of measured data. optimized for water/sewage water industry
Show ProductVEGATOR 141
VEGATOR 142
VEGASCAN 693
Measured value indication and remote enquiry of measured data for up to 15 HART sensors
Show ProductPLICSMOBILE T81
Measured data enquiry and remote parameter adjustment for a HART sensor
Show ProductVEGATRENN 141
VEGATRENN 142
VEGATRENN 151
Single channel separator in two-wire technology for 4 … 20 mA sensors
R 3,130.00
VEGATRENN 152
Double channel separator in two-wire technology for 4 … 20 mA sensors
R 4,570.00
Overvoltage protection B 81-35
Overvoltage protection B 63-32
Overvoltage protection for Profibus PA and Foundation Fieldbus circuits
R 3,920.00
Overvoltage protection B 63-48
Overvoltage protection B 62-30 W
Overvoltage protection for Profibus PA and Foundation Fieldbus circuits
R 2,790.00
Overvoltage protection B 62-36 G
VEGACONNECT
Interface adapter between PC and VEGA instruments
Show ProductVEGABOX 03
Breather housing with ventilation filter
Show ProductProfibus PA/DP segment coupler
Simple segment coupler for up to 93.75 kbit/s DP-side
Show ProductG1½ threaded adapter for VEGAFLEX 80 and VEGAPULS 64
VEGAFLEX series 80 cable and rod components
VEGAFLEX series 80 probe extensions
VEGAFLEX series 80 spacers
Spacers or centering weights fix the measuring probe in the middle of the tube.
Show ProductVEGAFLEX series 80 centering/gravity weights
FLEX80 tensioning facility for cable version of FLEX81, FLEX86
Antenna extension PLICSMOBILE
VEGADIS adapter
For connection of an external display and adjustment unit or a Secondary sensor.
Show ProductElectronics VEGAFLEX serie 80
Process component VEGAFLEX 86
PLICSMOBILE plug connector with SMA connection
Electronics PLICSMOBILE series 80
An error has occurred
An error occurred when starting the configurator. We have documented the error and are working on it.
Please try again later. Alternatively you can contact us directly.
Thank you very much for your understanding.
VEGAFLEX 86
myVEGA
With myVEGA as your personal information platform, you’ll have at your disposal numerous online functions revolving around the VEGA products.
- Configurator for the entire VEGA product range
- Information about prices and delivery times
- Order directly online
- Saving of configurations
- 2D/3D drawings of your configured instrument
- Overview of order transactions
Still no access?
Register for freeForgot password
Enter your e-mail address and we will send you a link to reset your password.
Reset password Cancel
Close