Reboiler
Level measurement in the reboiler
|
|
Process data
Measuring task:
Level measurement
Measuring point:
Reboiler
Measuring range up to:
3 m
Medium:
Various hydrocarbons
Process temperature:
+180 … +400 °C
Process pressure:
+10 … +35 bar
Special challenges:
Extreme temperatures, highly viscous medium
Application
Evaporators are heat exchangers that are deployed at the bottom of distillation columns. In the evaporator, the residue is boiled up from the sump and fed back into the distillation process. Precise control of the level in the evaporator ensures efficient operation of the plant. A reliable measurement also ensures that the heating coils are always covered with liquid, to prevent any overheating incidents.
Your benefit
Reliable
Safe and reliable measurement even at extreme temperatures
Cost effective
Maintenance-free operation
User friendly
Easy installation
Recommended products
VEGAFLEX 86
Level measurement with guided wave radar in the reboiler
- Reliable measurement unaffected by vapour presence and high temperatures
- Flexible mounting possibilities in the tank or in a bridle
- Robust material options are resistant to extreme process conditions
Measuring range - Distance
75 m
Process temperature
-196 ... 450 °C
Process pressure
-1 ... 400 bar
FIBERTRAC 31
Radiation-based sensor for continuous level measurement in the reboiler
- Non-contact operation is unaffected by process temperature
- Lightweight detector eliminates need for cranes or special rigging
- Small bend radius of flexible detector mounts to vessel shape
- Cost savings, as no servicing of the measuring system is required
Measuring range - Distance
7 m
Process temperature
-
Process pressure
-
Close