Clinker silo
Level measurement and point level detection in clinker silos
Process data
Measuring task:
Level measurement and point level detection
Measuring point:
Silo
Measuring range up to:
30 m
Medium:
Clinker
Process temperature:
-40 … +200 °C
Process pressure:
0 … 0 bar
Special challenges:
Dust, abrasion, high temperatures
Application
After the raw meal is burned, the emerging clinker of varying consistency is stored for further processing. The silos are filled and emptied through different openings. Continuous operation of the subsequent production processes is ensured by level measurement and point level detection.
Your benefit
Reliable
Reliable measurement despite high temperatures
Cost effective
Optimal stocks enable continuous production
User friendly
Maintenance-free operation
Recommended products
VEGAPULS 6X
Level measurement with radar in clinker silos
- Exact measurement right to the bottom of the discharge funnel thanks to small beam angle
- High measurement certainty, unaffected by dust and temperature changes
- Maintenance-free through non-contact measurement
Measuring range - Distance
120 m
Process temperature
-196 ... 450 °C
Process pressure
-1 ... 160 bar
VEGACAP 65
Capacitive point level detection in clinker silos
- Robust construction ensures a long service life
- Reliable measurement, unaffected by buildup
- Cut to length cable probes allow high flexibility
Measuring range - Distance
-
Process temperature
-50 ... 200 °C
Process pressure
-1 ... 64 bar
Close