Lime silo II
Level measurement and point level detection in the lime silo
|
|
Process data
Measuring task:
Level measurement and point level detection
Measuring point:
Silo
Measuring range up to:
30 m
Medium:
Lime
Process temperature:
-40 … +50 °C
Process pressure:
0 … 0 bar
Special challenges:
Strong dust generation and possible condensation
Application
For flue gas desulfurization a continuous production of the lime milk is required, the lime is kept on hand in sufficient quantities in large silos. Lime tends to readily adhere to more or less anything, depending on its type and consistency, interfering with equipment like the operation of instruments. A robust, non-susceptible level measurement is therefore absolutely necessary for reliable lime logistics and stocking. That’s why a non-contact measuring instrument that also works well in the very dusty environment is essential here.
Your benefit
Reliable
Reliable measurement even during filling
Cost effective
Accurate measurement of the entire container volume
User friendly
Simple mounting and setup
Recommended products
VEGAFLEX 82
The guided radar sensor measures the level in the lime silo
- Unaffected by dust and condensation
- Menu-driven adjustment allows simple, time-saving, confident setup
- Shortenable probes offer basic standardization and maximum flexibility in planning
Measuring range - Distance
75 m
Process temperature
-40 ... 200 °C
Process pressure
-1 ... 40 bar
VEGACAP 65
Capacitive cable probe as overfill protection in the lime silo
- Long service life and low maintenance requirements through robust mechanical design
- Shortenable probe allows high flexibility
Measuring range - Distance
-
Process temperature
-50 ... 200 °C
Process pressure
-1 ... 64 bar