email public shopping_cart 0
Select shopping cart

There are already products in the shopping cart of your user account. Which shopping cart would you like to keep?

Batching tank for coatings

Level measurement in the coating batching tank

Level measurement in the coating batching tank
Level measurement in the coating batching tank
Level measurement in the coating batching tank
Hydrostatic
Level measurement in the coating batching tank
Radar

Process data

Measuring task:
Level measurement
Measuring point:
Batching tank
Measuring range up to:
0.5 m
Medium:
Hot water with coating agent
Process temperature:
+20 … +50 °C
Process pressure:
0 … 0 bar
Special challenges:
Temperature change from cold to hot, low liquid levels, rapid filling

Application

The press rolls are cleaned during product changes or shutdowns of the paper machine and then treated with a special coating agent. This protects them from adhesions and deposits that could cause the paper web to tear or split in the machine. The coating agent is mixed with hot water in a batching tank at a temperature of 50 °C, and pumped to various points in the machine. To maintain automatic operation, the level in the batching tank must be measured and the filter status monitored continuously.

Your benefit

Reliable
Reliable level measurement despite extreme temperature changes
Cost effective
Accurate measurement even in small tanks
User friendly
Sensor removal during tank cleaning not necessary

Recommended products

Hydrostatic
Radar

Save application

Save this application as a PDF file.

PDF Download

Close