Mixing Vessel
Level measurement in the mixing vessel and pressure measurement in the supply line
|
|
Process data
Measuring task:
Level and pressure measurement
Measuring point:
Vessel
Measuring range up to:
1.2 m
Medium:
Antibiotics, injection and infusion solutions, blood plasma products
Process temperature:
+50 ... +150 °C
Process pressure:
-1 … +6 bar
Special challenges:
Changing product density, frequent cleaning cycles, small vessels
Application
Mixing vessels are applied for preparation, storage and transfer of a wide range of pharmaceutical products. These vessels are used for the manufacture of antibiotics, blood plasma products, and injection and infusion solutions. Following preparation, substances are transferred to a filling station. To ensure a reliable process, the liquid level in the mixing vessel must be reliably and continuously monitored.
Your benefit
Reliable
Certified hygienic design (3A/EHEDG) and approved materials according to EC 1935/2004 and FDA
Cost effective
Continuous operation with absolute hygiene
User friendly
Standardized adjustment, process data storable and transferable
Recommended products
VEGABAR 38
Pressure monitoring with IO-Link connection in the supply line of the heating medium
- Reliable measurement thanks to fast response time
- Robust ceramic CERTEC® measuring cell guarantees a long service life
- Simple operation thanks to VDMA menu structure and integrated display
Measuring range - Pressure
-1 ... 60 bar
Process temperature
-40 ... 130 °C
Accuracy
0.3 %
VEGPULS 6X
Level measurement with radar in the mixing vessel
- Reliable level measurement, independent of process conditions such as vacuum, pressure, temperature and changing product density
- Flange with encapsulated antenna system allows optimal CIP and SIP cleaning
- The small beam angle and good focussing of the sensor allows easy alignment
Measuring range - Distance
120 m
Process temperature
-196 ... 450 °C
Process pressure
-1 ... 160 bar