MINITRAC: Density measurement using the radiometric principle
![MINITRAC 31](/-/media/images/products/sensors/f-minitrac-radiometrischer-sensor-zur-grenzstanderfassung-und-dichtemessung-minitrac31-v01.png)
MINITRAC 31
Para o produto![MINITRAC 32](/-/media/images/products/sensors/f-minitrac-radiation-based-sensor-for-density-measurement-and-switching-minitrac32n.png)
MINITRAC 32
Para o produto![VEGASOURCE 81](/-/media/images/products/sensors/vegasource81-1aavxxxg11axxxa.png?mh=140&hash=8FD6AD583D531EADF268144A02A3FF13)
VEGASOURCE 81
Para o produto![VEGASOURCE 82](/-/media/images/products/sensors/vegasource82-1aa11agg11axxxa.png?mh=140&hash=330F044DC890C0790782B03C7A74BC3A)
VEGASOURCE 82
Para o produto![VEGASOURCE 83](/-/media/images/products/sensors/vegasource83-1aavxxxg11axxxx.png?mh=140&hash=6748331CAD6EF6164AEBDA3693EFFD45)
VEGASOURCE 83
Para o produto![VEGASOURCE 84](/-/media/images/products/sensors/3d-se84.png)
VEGASOURCE 84
Para o produto![VEGASOURCE 85](/-/media/images/products/sensors/3d-se85.png)
VEGASOURCE 85
Para o produto![VEGASOURCE 86](/-/media/images/products/sensors/3d-se86.png)
VEGASOURCE 86
Para o produtoFunctionRadiometric measurement is based on the gamma rays, i.e. radiation, emitted by an isotope. The sensor, located on the opposite side of the vessel, receives this radiation. The detector of the sensor converts the gamma radiation into signals, the number of which is recorded and evaluated. Series |
|
MountingThe radioactive source is mounted on one side of the container and the detector on the opposite side. Density and concentration measurement in pipelines and vessels is possible. The greater the irradiated distance, the higher the accuracy of the measurement. ConnectionA three-core installation cable with PE conductor is required for power supply. The 4 ... 20 mA current output is connected with standard two-wire cable. SetupDue to the measuring principle itself, there is no linear relationship between the pulse rate and the level. For that reason, an adjustment must always be carried out. |
FunctionRadiometric measurement is based on the gamma rays, i.e. radiation, emitted by an isotope. The sensor, located on the opposite side of the vessel, receives this radiation. The detector of the sensor converts the gamma radiation into signals, the number of which is recorded and evaluated. Series |
|
MountingThe radioactive source is mounted on one side of the container and the detector on the opposite side. Density and concentration measurement in pipelines and vessels is possible. The greater the irradiated distance, the higher the accuracy of the measurement. ConnectionA three-core installation cable with PE conductor is required for power supply. The 4 ... 20 mA current output is connected with standard two-wire cable. SetupDue to the measuring principle itself, there is no linear relationship between the pulse rate and the level. For that reason, an adjustment must always be carried out. |